- Tawhā me te huru
- Inquiry
Use And Operation
These valves are used to control actuator's movements and blockin one direction in order to have a under control descent of a load;load's weight doesn't carry it away, as the valve prevents any cavitations of the actuator.
tono
Connect V1 and V2 to the pressure flow, C1 to the free flow side of the actuatorand C2 to the actuator's side you want the flow to be blocked. In-line mounting.
Parameters me te ahua
Rauemi me nga ahuatanga
Body: Zinc-plated steel
Internal parts: hardened and ground steel
Hiri: BUNA N paerewa
Tightness: minor leakage
Standard setting:320bar
Valve setting must be at least 1,3 times more than load pressure in orderto enable the valve to close even when undergone to the maximum load pressure.