+ 86-18761016003

GPM3 ស៊េរី

អ្នកនៅទីនេះ៖ ទំព័រដើម >ផលិតផល >ម៉ាស៊ីនបូមធារាសាស្ត្រ >GPM3 ស៊េរី

ផលិតផល

  • /img/cbmw_type_compound_gear_pumps.jpg
  • /upfile/2019/01/22/20190122100727_337.jpg
  • /upfile/2019/01/22/20190122100735_539.jpg
  • /upfile/2019/01/22/20190122100743_526.jpg

ម៉ាស៊ីនបូមស៊ីម៉ងត៍ប្រភេទ CBMW ប្រភេទ

  • ការពិពណ៌នា
  • ប៉ារ៉ាម៉ែត្រនិងតួអក្សរ
  • សេវាកម្មរបស់យើង
  • ស៊ើបអង្កេត

CBMW series compound gear pump contains a monopolegear pump and a stable flow diverting valve,supply one main olcircuit and one stable oil circuit for the hydraulic system,also upto international advanced level.With characters:high pressure,high volumetric efficiency,long usage,with overloadprotection,can be widely used in every hydraulic system.

Model CBMW Dimensional Data


Parameters និងតួអក្សរ

ប៉ារ៉ាម៉ែត្រ

 

CBMW-F11

CBMW-F13.5

CBMW-F16

CBMW-F18

ការផ្លាស់ទីលំនៅ

mL/r

11

13.5

16

18

The Rated Pressure

MPa

 

18

សម្ពាធអតិបរិមា

MPa

22.5

Regulating Range

MPa

10-20

ល្បឿនដែលបានវាយតម្លៃ

r / នាទី

2000

Speed  Range

r / នាទី

1000-2500

Constant Flow

លីត្រ / នាទី

5

7

9

12

Oសេវាកម្មយូ

Iកំណត់ចំណាំ NSTALLATION  

មុនពេលចាប់ផ្តើមប្រព័ន្ធជាប្រចាំយើងស្នើឱ្យមានការប្រុងប្រយ័ត្នសាមញ្ញមួយចំនួន:

l Check for the direction of rotation of the pump to be consistent with the drive shaft one.

l Check for the proper alignment of pump shaft and motor shaft: it is necessary that the connection does not include axial or radial loads.

l Protect drive shaft seal during pump painting. Check if contact area between seal ring and shaft is clean: dust could provoke quicker wear and leakage.

l Remove all dirt, chips and all foreign bodies from flanges connecting inlet and delivery ports.

l Ensure that intake and return pipes ends are always below fluid lever and as far from each other as possible.

l Install the pump below head, if possible.

l Fill the pump with fluid, and turn it by hand.

l Disconnect pump drain during startup to bleed air off the circuit.

l At first startup, set pressure limiting valves at min. value possible.

l Avoid lower rotation speed than min. allowed with pressure higher than continuous max. pressure.

l Do not start the system at low temperatures under load conditions or after long stops (always avoid or limit load starting for pump longer life).

l Start the system for a few minutes and turn on all components; bleed air off the circuit to check its proper filling.

l Check fluid lever in the tank after loading all components.

l At last, gradually increase pressure, continuously check fluid and moving parts temperature, check rotation speed until you reach set operating values that shall be within the limits indicated in this catalogue.

 

 

វត្ថុរាវធារាសាស្ត្រ  

ប្រើវត្ថុរាវធារាសាស្ត្រដែលមានប្រេងរ៉ែជាក់លាក់មានលក្ខណៈប្រឆាំងនឹងការពាក់ល្អប្រឆាំងនឹងអុកស៊ីតកម្មប្រឆាំងអុកស៊ីតកម្មប្រឆាំងនឹងការច្រេះនិងលក្ខណៈរំអិល។ វត្ថុរាវក៏គួរតែអនុលោមតាមស្តង់ដារ DIN51525 និង VDMA 24317 និងឆ្លងកាត់ 11th ដំណាក់កាលនៃការសាកល្បងអេហ្វហ្សុជី។

ចំពោះម៉ូដែលស្តង់ដារសីតុណ្ហភាពនៃអង្គធាតុរាវមិនគួរស្ថិតនៅចន្លោះ -១០ ℃និង + ៨០ 。。

 

ជួរ viscosity kinematic រាវមានដូចខាងក្រោមៈ

តម្លៃដែលបានអនុញ្ញាត

6÷500 ស៊ីអេស

តម្លៃដែលបានណែនាំ

១០ ÷100 ស៊ីអេស

តម្លៃអនុញ្ញាតនៅពេលចាប់ផ្តើម

<2000 ស៊ីអេស

Iការសាកល្បង
  

ចុះឈ្មោះនិងរក្សាទុក!ការផ្តល់ជូនអ៊ីម៉ែលផ្តាច់មុខនិងពិសេសការបញ្ចុះតម្លៃពេលវេលាមានកំណត់

កញ្ចប់សាកសួរ
ទទេសំណួរ